10/14/20MM Fire Protection Insulation Board


Category: MGO fireproof board

Relevant certificates: UL / SGS / MA / CNAS / EACC / IAF / Review of Fire Test Report / Class O Summary Report / Certificate of Compliance Normal thickness: 10MM / 14MM / 20MM / 25MM / 30MM Fireproof rating: A1 Fire resistance duration: 60 min /120 min Product features:Fire resistance, flame retardancy, compression resistance, good sealing, etc

  • Product overview
    • Commodity name: 10/14/20MM Fire Protection Insulation Board

    Relevant certificates: UL / SGS / MA / CNAS / EACC / IAF / Review of Fire Test Report / Class O Summary Report / Certificate of Compliance Normal thickness: 10MM / 14MM / 20MM / 25MM / 30MM Fireproof rating: A1 Fire resistance duration: 60 min /120 min Product features:Fire resistance, flame retardancy, compression resistance, good sealing, etc

    Product description

     

    This Fire Barrier slab has been developed to prevent the spread of flames and inhibit heat and smoke through concealed spaces in buildings and improve sound reduction. 
    The thicker the board the more time the fireboard will hold up and not deteriorate in the event of a fire. For instance, a 15mm fireboard will last for up to 60min, 12mm will last 45 minutes, 9mm will last one half an hour, and so on. Remember, if there is a hole in the board to allow for wiring, this will eliminate the protection that the fireboard provides. When used in a partition or ceiling, two layers of 12.5mm fire plasterboard should provide up to one hour’s fire protection. In a partition where there are two layers of fire-rated plasterboard on either side, they will provide up to two hours of fire resistance.

     
     

    Sheet parameters

     

    Single-sided color steel magnesium smoke exhaust duct

     

    Plate thickness:14-20mm

    Plate specification:1200(mm)×2400(mm)

    Fire rating:non-combustible A1

    Plate weight:10-15kg/㎡

    Material composition:color steel plate+magnesium fireproof plate

    Fire resistance time:0.5h,1.0h,1.5h,2.0h

    Scope of application: air supply duct, smoke exhaust duct, air supply duct with fire resistance requirements, fire resistant air duct passing through fire compartment

    Double-sided color steel magnesium smoke exhaust duct

     

    Plate thickness:14-20mm

    Plate specification:1200(mm)×2400(mm)

    Fire rating:non-combustible A1

    Plate weight:12-17kg/㎡

    Material composition:color steel plate+magnesium fireproof plate+color steel plate

    Fire resistance time:0.5h,1.0h,1.5h,2.0h

    Scope of application: smoke exhaust plant project with specific requirements.

     
     